Apart from the highest quality components and engineering, what makes Bravo special is the inbuilt stabilizer and charger. With Bravo there is no need to purchase an additional voltage stabilizer, or a charger for charge recovery in case the battery is exhausted. This is why it is becoming the most popular sine-wave UPS in the market.
Specifications
Model Name |
Bravo 5000 |
Mains AC low cut UPS mode |
175VAC ± 10VAC |
Mains AC low cut recovery UPS mode |
185VAC ± 10VAC |
Mains AC high cut UPS mode |
265VAC ± 10VAC |
Mains AC high cut recovery UPS mode |
255VAC ± 10VAC |
Mains AC low cut WUPS mode |
90VAC ± 10VAC |
Mains AC low cut recovery WUPS mode |
110VAC ± 10VAC |
Mains AC high cut WUPS mode |
295VAC ± 10VAC |
Mains AC high cut recovery WUPS mode |
285VAC ± 10VAC |
Input Frequency Range |
40Hz to 60Hz |
Battery
Battery Type |
LA / Tubular / SMF |
DC input voltage |
12V |
Battery deep Discharge Recovery |
Yes (Independent Charger to Recover Deep Discharge Battery) |
Charging Current 100Ah-135Ah Setting (Input range 135VAC to 295VAC) |
12A ± 1A |
Charging Current 150Ah-220Ah Setting (Input range 135VAC to 295VAC) |
15A ± 1A |
Boost charging voltage for LA Battery |
56.0V±0.4V |
Boost charging voltage for Tubular and SMF Battery |
58.0V±0.4V |
Backup Mode
Output voltage |
220VAC +5% -10% (untill battery low alarm) |
Output frequency |
50Hz ± 0.2 Hz |
Output waveform |
Pure Sine Wave |
Capacity |
5000 VA |
Low Battery Warning |
44V±0.4V |
Low Battery Cut |
43V±0.4V |
Change over time UPS mode |
< 10msec |
Change over time WUPS mode |
< 25msec |
Protections
Overload /Short Ckt. in backup mode |
Available |
Backfeed |
System will shutdown in case of backfeed and there is no retry |
Over temperature |
Available |
Reverse Battery |
Available |
Phase to Phase protection in mains mode |
Available |
Display and Alarms
LCD Status Display |
Mains ON, Input -Voltage/ Frequency, Battery -Voltage/Charging/Charged, UPS ON-OFF, Load,Output Voltage etc and all fault messages |
Buzzer |
Audible beep for all protections |
Environment
Operating Temperature |
0° C To 50° C |
Storage Temperature |
0° C To 50° C |
Operating Relative Humidity |
90% Non-Condensing |